Cameras and detectors are where EPICS stops being about small numbers and starts being about data rates. One framework dominates.

areaDetector

   
Organisation github.com/areaDetector
Core ADCore
Documentation areadetector.github.io
Maintainer Mark Rivers (APS) and a large community
Training AreaDetector (USPAS)

areaDetector is big enough to have its own GitHub organisation, because each detector driver is a separate repository. The architecture:

flowchart LR
    DRV["Driver<br/>ADPilatus, ADAravis,<br/>ADSimDetector…"]
    subgraph PL["Plugin chain (NDArray in → NDArray out)"]
        direction TB
        ROI["NDPluginROI<br/>crop"]
        STAT["NDPluginStats<br/>centroid, profiles"]
        PROC["NDPluginProcess<br/>background, flat field"]
        CB["NDPluginCircularBuff<br/>pre-trigger buffer"]
        HDF["NDFileHDF5<br/>write"]
        PVA["NDPluginPva<br/>serve as NTNDArray"]
        STD["NDPluginStdArrays<br/>serve as waveform"]
    end
    DRV --> ROI --> STAT
    DRV --> PROC --> HDF
    DRV --> CB
    DRV --> PVA
    DRV --> STD

The model: a driver produces NDArray objects into a queue. Plugins consume NDArrays and may produce more. Every plugin is independently configurable at runtime, has its own queue, and can be enabled or disabled without restarting. You wire up the chain you need in st.cmd and reconfigure the topology live.

Consequences worth understanding:

Drivers

Roughly forty, covering:

Category Drivers
Area detectors ADPilatus, ADEiger (Dectris), ADPerkinElmer, ADDexela, ADLambda, ADMerlin, ADPSL, ADmar345, ADmarCCD
Industrial cameras ADAravis (GenICam/GigE Vision), ADSpinnaker and ADPointGrey (FLIR), ADVimba (Allied Vision), ADAndor / ADAndor3, ADPCO, ADPvCam (Photometrics), ADURL (anything with an HTTP image), ADUVC (USB webcams)
X-ray detectors ADPilatus, ADEiger, ADXspress3, ADMythen, ADeVision
Electron/other ADProsilica, ADFastCCD, ADQ (SP Devices digitisers)
Simulation ADSimDetector — generates test patterns; the right starting point for learning

If your camera speaks GenICam/GigE Vision (most industrial cameras do), ADAravis is likely all you need.

File-writing plugins

Plugin Format
NDFileHDF5 HDF5, including NeXus-compatible layouts, compression (blosc, szip, zlib), and SWMR for reading while writing
NDFileTIFF, NDFileJPEG, NDFilePNG Single-image formats
NDFileNetCDF netCDF
NDFileNexus NeXus via an XML layout template
NDFileMagick Anything ImageMagick supports

HDF5 with compression is the default choice for serious data. SWMR (single-writer/multiple-reader) matters operationally: it lets analysis start on a file that’s still being written, which is the difference between live feedback and waiting for a scan to end.

Serving images to clients

Plugin Protocol Use
NDPluginStdArrays CA waveform Legacy; works everywhere, no metadata, and CA array size limits bite
NDPluginPva PVA NTNDArray The right answer. Dimensions, data type, unique ID, timestamp, codec and per-frame attributes travel with the pixels as one structure

This is the clearest practical case for PV Access: a CA waveform of pixels is just numbers, and you must reconstruct the geometry from separate PVs that may not be consistent with the frame you’re holding. NTNDArray makes the image self-describing and atomic.

Analysis plugins

NDPluginStats (centroid, sigma, profiles, histogram — the backbone of beam-position-from-camera measurements), NDPluginROI and NDPluginROIStat (multiple regions, each with statistics), NDPluginProcess (background subtraction, flat field, recursive averaging), NDPluginTransform (rotate/flip), NDPluginColorConvert, NDPluginOverlay (crosshairs and boxes drawn into the image for operators), NDPluginAttribute, NDPluginTimeSeries, NDPluginFFT, NDPluginCodec (compression/decompression), NDPluginCircularBuff (pre-trigger buffering — capture the N frames before an event), and NDPluginPosPlugin (tags frames with positions for continuous scanning).

Doing statistics in the plugin chain rather than in a client is usually right: it runs at IOC priority, produces ordinary PVs that the archiver and alarm system can consume, and doesn’t depend on anyone’s workstation being awake.

Data rate reality

The arithmetic that determines your architecture:

Detector Frame Rate Raw data rate
USB webcam 640×480×8 bit 30 fps 9 MB/s
GigE industrial camera 2048×2048×16 bit 20 fps 160 MB/s
Dectris Eiger 4M 2068×2162×32 bit 750 Hz ~13 GB/s
Fast X-ray detector at a 4th-gen source 10s of GB/s

Which forces, in order:

  1. A dedicated network for detector data. A 160 MB/s camera is 1.3 Gbit/s — it does not belong on the VLAN carrying your vacuum readings. See network design.
  2. Compression in the detector or the plugin chain, not afterwards. NDPluginCodec with blosc costs CPU and saves a great deal of I/O.
  3. Direct-to-storage paths for the fastest detectors, bypassing EPICS entirely: the detector writes to a parallel filesystem and EPICS handles control, metadata and monitoring only. Above roughly 1 GB/s this is the only workable architecture.
  4. Never routing full-rate data through CA/PVA to clients. Serve a downsampled or ROI’d view for operators; the science data goes to files.

The general principle: EPICS controls the detector; it does not have to carry the detector’s output. Newcomers often assume every byte must flow through the control system. It mustn’t, and at high rates it can’t.

Tool Purpose
ADSupport Bundled third-party libraries (HDF5, TIFF, JPEG, zlib, blosc) so areaDetector builds without hunting system packages
ADViewers Image viewers: ImageJ plugins, a Python PVA viewer
pvapy Python PVA, widely used for NTNDArray processing pipelines
Bluesky / ophyd Orchestrating detectors within experiments
Tiled Serving the resulting data to analysis clients

Practical guidance

Start with ADSimDetector. Build the whole plugin chain, the screens, the file writing, and the scan integration against simulated frames. Then swap in the real driver. This also gives you a permanent CI test.

Watch the dropped-frame counters. Put them on the operator screen and in the alarm system. A detector quietly dropping 2% of frames produces data that looks fine and isn’t.

Understand your acquisition modes. Single, Multiple, Continuous, and external-trigger modes behave differently in the driver, and the interaction between NumImages, NumExposures, TriggerMode and the plugin chain is where most commissioning time goes.

Put per-frame metadata in NDAttributes. Sample name, motor positions, ring current, monochromator energy — attached to the frame via NDAttributesFile, so it lands in the HDF5 file automatically and travels with the data forever. Metadata reconstructed later from archived PVs is a poor substitute and sometimes impossible.

Think about disk before commissioning. A detector that fills a filesystem stops an experiment, and “where do the files go, who deletes them, and when” is a policy question that must be answered before beam, not after.